New York City Water Based Fire Sprinkler Systems
Automatic fire sprinklers installed in your office or home residence will significantly limit the potential loss for life, valuables, and prized possessions. The New York Fire Department has information regarding New York State Fire Codes Rules and Regulations, which may help during the installation, remodel or retrofit of a water based fire sprinkler system.
New York City Fire Sprinklers
Water Based Fire Sprinklers
- Water based fire sprinklers
- Wet pipe fire sprinklers
- Dry pipe fire sprinklers
- Pre action fire sprinklers
- Combined fire sprinklers
- Antifreeze fire sprinklers
- Deluge fire sprinklers
- Foam fire sprinklers
Standpipe Fire Sprinkler Systems
- Standpipe fire sprinklers
- Wet standpipe fire sprinklers
- Dry standpipe fire sprinklers
- Pre action standpipe fire sprinklers
- Combined standpipe fire sprinklers
- Antifreeze standpipe fire sprinklers
- Standpipe hose connections
- Temporary standpipes
Specific Fire Sprinkler Systems
Maintenance will be required on your water based fire sprinkler system the NFPA 25 states, “1.1* Scope. This document establishes the minimum requirements for the periodic inspection, testing, and maintenance of water-based fire protection systems, including land-based and marine applications. 1.1.1 This standard does not address all of the inspection, testing, and maintenance of the electrical components of the automatic fire detection equipment for pre-action and deluge systems that are addressed by NFPA 72, National Fire Alarm Code. The inspection, testing, and maintenance required by this standard and NFPA 72, National Fire Alarm Code, shall be coordinated so that the system operates as intended. 1.1.2 The types of systems addressed by this standard include, but are not limited to, sprinkler, standpipe and hose, fixed water spray, and foam water. Included are the water supplies that are part of these systems, such as private fire service mains and appurtenances, fire pumps and water storage tanks, and valves that control system flow. The document also addresses impairment handling and reporting. This standard applies to fire protection systems that have been properly installed in accordance with generally accepted practices. Where a system has not been installed in accordance with generally accepted practices, the corrective action is beyond the scope of this standard. The corrective action to ensure that the system performs in a satisfactory manner shall be in accordance with the appropriate installation standard. 1.1.3 This standard shall not apply to sprinkler systems designed and installed in accordance with NFPA 13D, Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes. A.1.1 Generally accepted NFPA installation practices for water-based fire protection systems relevant to this standard are found in the following: NFPA 13, Standard for the Installation of Sprinkler Systems. NFPA 13R, Standard for the Installation of Sprinkler Systems in Residential Occupancies up to and Including Four Stories in Height. NFPA 14, Standard for the Installation of Standpipe and Hose Systems. NFPA 15, Standard for Water Spray Fixed Systems for Fire Protection. NFPA 16, Standard for the Installation of Foam-Water Sprinkler and Foam-Water Spray Systems. NFPA 20, Standard for the Installation of Stationary Pumps for Fire Protection. NFPA 22, Standard for Water Tanks for Private Fire Protection. NFPA 24, Standard for the Installation of Private Fire Service Mains and Their Appurtenances. NFPA 750, Standard on Water Mist Fire Protection Systems. For systems originally installed in accordance with one of these standards, the repair, replacement, alteration or extension of such systems should also be performed in accordance with that same standard. When original installations are based on other applicable codes or standards, repair, replacement, alteration, or extension practices should be conducted in accordance with those other applicable codes or standards.”